Temperature Digital Display Type Electronic Switch

Model NO.: XTWK Series
Trademark: SHUA
Origin: Tianchang City, Anhui Prov, Chn
Model NO.: XTWK Series
Trademark: SHUA
Origin: Tianchang City, Anhui Prov, Chn
, Summary
XTWKseries of digital electronic temperature switch using PT100 sensor. Reliable quality, advanced technology, small volume, light weight, directinstallation, output, lower two relay switch signal and 4-20mA for subsequentinterlocking control or alarm. Can be used in industrial process control and scientific research and other key places, and may provide for the followingplaces:
* require current telemetering and alarm, place.
* can be used for a long time in the open air.
* the intrinsically safe type can be used in hazardous locations.
* can be directly installed in the pipeline, equipment, without mounting bracket.
* can not open the lid of the case, the external key continuous adjustment, alarmand alarm hysteresis value.
, Characteristic
1, the 3A relay switch output.
2, 0.56# large screen LED display.
3, 4-20mA output current and lower limit alarm value, in the range of adjustable.
, The main technical indicators
1, the thermometric medium: Any medium and so compatible.
2, the measurement range: The user specified.
3, accuracy (including linear, repetitive, Chi Zhi): +-0.2%, +-0.5%
4, the output: , lower limit switch, 4-20mA linear current output.
5, the alarm point back to the difference: 0-777 set, generally range 5-10%, according to the specific requirements of the field control.
6, structure and materials:
Shell ABS waterproof box
100*68*50 size (width * high * thick)
Enclosure protection with IEC IP62
7, the process connection mode:
M20*1.5 screw, M27*2 screw, or the specified thread.
8, the power supply voltage: AC/DC 100-240V, AC/DC 24V choose. , Summary
XTWKseries of digital electronic temperature switch using PT100 sensor. Reliable quality, advanced technology, small volume, light weight, directinstallation, output, lower two relay switch signal and 4-20mA for subsequentinterlocking control or alarm. Can be used in industrial process control and scientific research and other key places, and may provide for the followingplaces:
* require current telemetering and alarm, place.
* can be used for a long time in the open air.
* the intrinsically safe type can be used in hazardous locations.
* can be directly installed in the pipeline, equipment, without mounting bracket.
* can not open the lid of the case, the external key continuous adjustment, alarmand alarm hysteresis value.
, Characteristic
1, the 3A relay switch output.
2, 0.56# large screen LED display.
3, 4-20mA output current and lower limit alarm value, in the range of adjustable.
, The main technical indicators
1, the thermometric medium: Any medium and so compatible.
2, the measurement range: The user specified.
3, accuracy (including linear, repetitive, Chi Zhi): +-0.2%, +-0.5%
4, the output: , lower limit switch, 4-20mA linear current output.
5, the alarm point back to the difference: 0-777 set, generally range 5-10%, according to the specific requirements of the field control.
6, structure and materials:
Shell ABS waterproof box
100*68*50 size (width * high * thick)
Enclosure protection with IEC IP62
7, the process connection mode:
M20*1.5 screw, M27*2 screw, or the specified thread.
8, the power supply voltage: AC/DC 100-240V, AC/DC 24V choose.

Fan Heater

Heater is a combination of fans, motors and air heaters combined unit. Applicable to all types of workshops, when the air is free of dust and flammable or explosive gas, can be used as a circulating air heating. Heater can be used independently as a heating, generally used to supplement the lack of heat sink parts or the use of radiators as the duty of heating, the remaining heat load borne by the heater.

(1) horizontal blower: indoor air from the side of the inhalation, the heat exchanger after the heat, the horizontal direction. The jet has a certain range, so that the heating zone is fully blended, the temperature is evenly mixed.

(2) top blower fan: axial fan placed in the bottom of the unit, the air from the side of the heater into the air through the standing heat exchanger, and then sent down. In order to make the jet face to be discharged downward, a guide vane for diffusion is provided at the outlet of the fan.

(3) floor heaters: such units of the large amount of air, send hot air range far, can afford a larger area of heating. When running, the noise is large. Applicable to the factory building heating.

The advantage of heater heating is [2]:
(1) single machine heat supply, in the same heat load, the number of end devices used less;
(2) small heaters can be hanging, do not take up the building area, large heaters floor installation, covers an area of limited;
(3) start heating up fast.

Fan Heater

Fan Heater, Portable Electric PTC Fan Heater, Square Nice Electric Heater, Desktop Portable Electric Fan Heater

Ningbo APG Machine(appliance)Co.,Ltd , http://www.apgelectrical.com